E-FSC Conventional Fire Alarm Control Panel

Specifications

  • Device loops:1 loop Class B, Class A optional, supporting up to 64 device addresses
  • NAC Circuits:2 Class B, Class A optional, 2.5 amps each
  • Power supply75A FWR total at 120/230V AC 60 Hz; 3.0A FWR total at 230V AC 50 Hz; 0.5A aux power
  • Operating Voltage:24V DC. NAC minimum voltage: 19.5V DC @ 20.4V battery voltage
  • Loop circuit operating voltage:20V peak-to-peak
  • Primary power:120V AC 60 Hz, 230V AC 50 – 60 Hz
  • Aux Power 1 (Continuous Circuit):24V DC nominal at 500 mA
SKU: E-FSA64 Categories: , ,

The E-FSC fire alarm family consists of 3, 5 and 10 zone conven-tional fire alarm control panels, an integrated DACT/Dialer, serial annunciator modules, and serial remote relay modules. All of these components are microprocessor-controlled. The E-FSC family is ideal for both new and retrofit installations alike.

E-FSC incorporates features designed to simplify installation, opera-tion and maintenance. These include front panel programming, one person walk testing, and selectable IDC and NAC types. In addition, when used with Edwards CleanMe® -compatible smoke detectors, E-FSC provides analog type features such as remote maintenance alert and automatic drift compensation that reduces false alarms and simplifies maintenance calls.

E-FSC502 and E-FSC1004 panels support Class A operation by combining pairs of on-board initiating curcuits (IDCs) or notifica-tion circuits (NACs) to provide the necessary Class A circuits. For example, the E-FSC1004 comes factory set to support 10 Class B IDCs and four NACs. But it can be field-configured to provide five Class A IDCs, no Class B IDCs, and two Class A NACs – or any other combination of circuits that fall within the circuit-pairing parameters.

Standard Features

  • Available in 3, 5, and 10 IDC models
  • IDC or NAC pairs convertible to single Class A circuits (10 and 5 IDC panels only)
  • CleanMe® provides remote annunciation if a detector drifts out of UL/ULC limits reducing the chance of a false alarm
  • Combination Waterflow and Supervisory IDCs reduces wire and zone counts
  • NACs programmable by zone and individually selectable for Genesis, continuous, temporal outputs, or coded
  • Front panel programmable simplifies installation and servicing
  • Optional fully integrated DACT/Dialer for remote PC programming
  • Genesis option allows precision synchronization and audible silence over two wires without additional modules
  • On-board relays for Alarm, Supervisory and Trouble
  • Optional serial bus relay modules are programmable for com-mon or zone activation
  • Optional serial bus remote annunciator family
  • One person walk-test (audible or silent)
  • Expandable power supply on 10 IDC panel reduces booster power costs
  • Trim ring available for semi-flush mounting
  • Supports 2M, “SC”, 2400, 500, and 700 series detectors

 

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.