Five Zone Fire Alarm Control Panel

The SFP-5UD is a five-zone FACP (Fire Alarm Control Panel) and the SFP-10UD(E) is a ten-zone FACP. These control pan- els provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download.

Each of these FACPs is compatible with System Sensor’s microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to

the FACP indicating the need for cleaning and a supervisory “freeze” signal when the ambient temperature falls below the detector  rating.  Additionally,  both  the  SFP-5UD  and  SFP-

10UD are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Refer to the Notifier Device Compatibility Document for a complete listing of compatible devices.

Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity.

Activation of a compatible smoke detector or any normally- open fire alarm initiating device will activate audible and visual signaling  devices, illuminate an  indicating LED,  sound  the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function.

The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line.

NOTE: The   SFP-10UDE offers the same features as the SFP-

10UD but allows connection to 240 VAC.  Unless otherwise speci- fied, the information in this data sheet applies to both the 120 VAC and the 240 VAC versions of these panels.

NOTE: For ULC-listed models, see dn-60437.

 

Features

  • Listed to UL Standard 864, 9th edition.
  • Built-in DACT (Digital Alarm Communicator/Transmitter).
  • Style B (Class B) IDC (Initiating Device Circuit)

SFP-5UD – five IDCs.

SFP-10UD – ten IDCs.

  • Style Y (Class B) NAC (Notification Appliance Circuit) – spe- cial application power

SFP-5UD – four NACs.

SFP-10UD – four NACs.

  • Notification Appliances may be programmed as

Silence Inhibit.

Auto-Silence.

 

 

Strobe Synchronization for  System Sensor, Wheelock, Gentex, Faraday, or Amseco devices.

Selective Silence (horn-strobe mute).

Temporal or Steady Signal.

Silenceable or Nonsilenceable.

  • Optional N-CAC-5X Style Z (Class A) Converter Module for

NACs and IDCs (2 required for SFP-10UD).

  • Form-C Relays for Alarm, Trouble and Supervisory – Con- tact Ratings 2.0 A@ 30 VDC or 30 VAC (resistive).
  • 3.0 A total system current for SFP-5UD.
  • 7.0 A total system current for SFP-10UD.
  • Optional Dress Panel DP-51050 (red)
  • Optional Dress Panel DP-51050B (black).
  • Optional Trim Ring TR-CE/-B for semi-flush mounting.
  • 24 volt operation.
  • Low AC voltage sense.
  • Alarm Verification.
  • PAS (Positive Alarm Sequence).
  • Automatic battery trickle charger.
  • Up to eight ANN-BUS annunciators:

Optional 8 zone Relay Module N-ANN-RLY.

Optional LED Annunciator Module N-ANN-LED,

Optional Remote LCD Annunciator N-ANN-80.

Optional Remote Printer Gateway N-ANN-S/PG.

Optional LED Annunciator Driver N-ANN-I/O.

  • Optional 4XTM module (conventional reverse polarity/city box transmitter).

 

PROGRAMMING AND SOFTWARE:

  • Can be programmed at the panel with no special software or additional equipment.
  • Programmable Make/Break Ratio.
  • Upload/Download (local or remote) of program and data via integral DA

 

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.