SIMPLEX 40008 Addressable Control Panel

Features
Control panel operator convenience features:
  -Wide viewing angle 2 x 20 ( 40 character) alphanumeric LCD and dedicated LEDs provide convenient panel status information
  – Operation is programmable using a multi-function keypad and the panel LCD or via service computer ( PC)
  – RS-232 service port provides upload/ download PC access for panel configuration and event history logs
  – Software updates are via PC download
 – Convenient library of standard custom label terms
  – Standard on-board DACT provides: Contact ID, 3/ 1, 4/ 2, BFSK, and SIA formats
  – WALKTEST™ silent or audible system test* *
  – Voltage and current for both the battery charger and the battery can be displayed at the front panel LCD

Description

For areas requiring up to 200 addressable input devices and up to 4 NACs, the Simplex 4008 Series fire alarm control panels provide flexible initiating circuit monitoring, extensive programmable control capability, and LCD annunciated circuit-specific 20 character custom labels.

Standard Feature Details
Addressable operation is provided by an IDNet signaling line circuit ( SLC) capable of communicating to up to 200 addressable devices ( points) . Addressable devices
include: TrueAlarm smoke detection, heat detection, and duct detection; supervised addressable modules for single and multiple contact monitoring, manual stations, isolation
modules, and a remote signal module. ( Please note that this panel provides a limited TrueAlarm operation feature set. For larger applications that require the
full complement of TrueAlarm features, contact your local Simplex product supplier.)

Two, 2 A On-Board NACs provide conventional reverse polarity operation, selectable as Class A or Class B, with electronic control and overcurrent protection. Operation is selectable for synchronized strobe or SmartSync™ horn/ strobe two wire operation. Horn control can be selected at the panel for: Temporal pattern coding, Steady On, Slow March Time of 20 beats per minute ( BPM) , or Fast March Time of 120 BPM. Note: When selected for SmartSync horn/ strobe control, March Time produces 60 BPM.

The 24 VDC Auxiliary output provides up to 500 mA for system use. ( Auxiliary output current is counted for total power supply capacity.)

Standard Auxiliary Relay Outputs.
Two relay outputs are available, selectable as normally open or normally closed, rated 2 A @ 30 VDC per below:
Aux Relay 1 is normally assigned to General Alarm operation but is programmable
Aux Relay 2 ( Trouble) is energized when Normal and is de-energized with a Trouble condition.

 

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.